[ Pobierz całość w formacie PDF ]
.73 1.Power line malfunction.1.Recycle power.Control board 2.Control board.2.Replace control board.77 1.Power line malfunction.1.Recycle power.Communication lines 2.Wire connections 2.Check wiring betweenbetween control board and control board and displaydisplay board.board.3.Display board.3.Replace display board.4.Control board.4.Replace control board.79 1.Door gasket.1.Clean or replace.Leak test failure (exceeds 2.Solenoid valve 1SOL 2.Clean or repair.2.7mm Hg/min) or a total not closing.of 0.783 psia 3.Solenoid valve 3SOL 3.Clean or repair.not closing.4.Chamber drain check 4.Clean or repair.valve(s) not closed.CAUTIONSCODE/MALFUNCTION POSSIBLE CAUSE REMEDY02 1.Water supply shut off.1.Turn on water supply.Negative pulse retarded 2.Water pressure 2.Check and ensure waterexceeds the following inadequate.supply pressure is 30-70 psigtimes: dynamic.16x16: 5 minutes 3.Door gasket.3.Clean or replace.20x20: 8 minutes 4.Chamber drain screen 4.Clean screen.clogged.5.Solenoid valve 2SOL 5.Clean or repair.not opening properly.6.Solenoid valve 1SOL 6.Clean or repair.not closed.7.Solenoid valve 3SOL 7.Clean or repair.not closed.8.Solenoid valve 6SOL 8.Clean or repair.not opening properly.MD0354 A-1 Coded Troubleshooting Guide (continued)CAUTIONS (continued)CODE/MALFUNCTION POSSIBLE CAUSE REMEDY04 1.Exposure temperature 1.Reset exposurePositive pulse retarded setting incorrect.temperature.(exceeds 5 minutes) 2.Steam supply shut off.2.Turn on steam supply.3.Steam pressure 3.Check and ensure steaminadequate.supply pressure is 40-50psigdynamic.4.Solenoid valve 2SOL 4.Clean or repair.not closed.5.Solenoid valve 1SOL 5.Clean or repair.not opening properly.6.Solenoid valve 8SOL 6.Clean or repair.not opening properly.7.Steam supply strainer 7.Clean strainer.plugged.8.Pressure release 8.Repair jacket trap.through jacket trapexcessive.9.Pressure release 9.Repair chamber trap.through chamber trapexcessive.06 (16x16) 1.Exposure temperature 1.Reset exposureTemperature retarded setting incorrect.temperature.exceeds the following 2.Steam supply shut off.2.Turn on steam supply.times: 3.Steam pressure 3.Check and ensure steamWrapped goods  inadequate.supply pressure is 40-50psig4 minutes dynamic.Unwrapped instruments - 4.Solenoid valve 2SOL 4.Clean or repair.6 minutes not closing properly.Liquids - 25 minutes 5.Solenoid valve 1SOL 5.Clean or repair.not opening properly.6.Solenoid valve 8SOL 6.Clean or repair.not opening properly.7.Steam supply strainer 7.Clean strainer.plugged.8.Pressure release 8.Repair chamber trap.through chamber trapexcessive.MD0354 A-2 Coded Troubleshooting Guide (continued)CAUTIONS (CONTINUED)CODE/MALFUNCTION POSSIBLE CAUSE REMEDY06 (20x20)/ 1.Exposure temperature 1.Reset exposureTemperature retarded setting incorrect.temperature.exceeds the following 2.Steam supply shut off.2.Turn on steam supply.times: 3.Steam pressure 3.Check and ensure steamWrapped goods - 4 inadequate.supply pressure is 40-50psigminutes dynamic.Unwrapped instruments - 4.Solenoid valve 2SOL 4.Clean or repair.9 minutes not closing properly.Liquids - 30 minutes 5.Solenoid valve 1SOL 5.Clean or repair.not opening properly.6.Solenoid valve 8SOL 6.Clean or repair.not opening properly.7.Steam supply strainer 7.Clean strainer.plugged.8.Pressure release 8 Repair chamber trap.through chamber trapexcessive.10 1.Steam supply shut off.1.Turn on steam supply.Exposure temperature 2.Steam pressure 2.Check and ensure steamreset (set point -2OC) inadequate.supply pressure is40-50psig dynamic.3.Solenoid valve 2SOL 3.Clean or repair.not closing properly.4.Solenoid valve 1SOL 4.Clean or repair.not closing properly.5.Solenoid valve 8SOL 5.Clean or repair.not closing.6.Chamber drain screen 6.Clean screen.clogged.14 1.Exposure temperature 1.Reset exposureExcessive exposure setting incorrect.temperature.temperature (exceeds 2.Solenoid valve 1SOL 2.Clean or repair.6OC over set point) not closing properly.3.Solenoid valve 8SOL 3.Clean or repair.not closing properly.18 1.Air-in filter.1.Replace filter.Air-in retarded (exceeds 2 2.Solenoid valve 3SOL 2.Clean or repair.minutes) not opening properly [ Pobierz całość w formacie PDF ]

  • zanotowane.pl
  • doc.pisz.pl
  • pdf.pisz.pl
  • blondiii.htw.pl
  •